Siemens Biograph 40 (TruePoint)
Family: Siemens Biograph TruePoint · Modality: PET/CT
40-slice intermediate tier in the Siemens Biograph TruePoint family. Shares the LSO PET detector architecture with Biograph 16 and Biograph 64, paired with a 40-slice CT derived from the SOMATOM Sensation 40 platform — the CT side brings z-Sharp flying focal spot and the STRATON tube into the PET/CT integrated system. Biograph 40 is less common than Biograph 16 (cost-down entry) and Biograph 64 (premium flagship of its era) but appears meaningfully in the secondary market.
Platform highlights
- LSO PET detector — 4.0 × 4.0 × 20 mm crystals; same detector architecture as Biograph 16 / 64 TruePoint class.
- Transaxial FOV 605 mm · Axial FOV 162 mm (216 mm with TrueV option).
- ToF-capable revisions — ~540 ps coincidence timing on ToF-configured units.
- 40-slice CT side — shares chassis and tube lineage with SOMATOM Sensation 40. STRATON tube, z-Sharp flying focal spot, CARE Dose4D.
- Integrated syngo host — shared Siemens operator environment across PET and CT.
CT side (Sensation 40 lineage)
The CT portion of Biograph 40 matches the Sensation 40 standalone CT architecturally:
- 32-row physical UFC detector with z-Sharp flying focal spot → 40 reconstructed slices.
- 0.33 s minimum rotation on cardiac-capable configurations.
- STRATON tube (liquid-metal-bearing rotating anode).
- 80 kW high-frequency generator.
Specs
- LSO PET (4.0 × 4.0 × 20 mm)
- Transaxial FOV 605 mm · Axial FOV 162 mm / 216 mm TrueV
- 40-slice CT (Sensation 40 lineage)
- STRATON tube · z-Sharp flying focal spot · CARE Dose4D
- ToF ~540 ps (ToF-configured revisions)
- syngo CT + PET host
Clinical positioning
- Mid-volume oncology PET/CT where 40-slice CT capability is clinically useful — cardiac CTA overlaid with cardiac PET, whole-body staging with diagnostic-quality CT.
- Cardiac PET/CT — rubidium myocardial perfusion with CT attenuation correction and diagnostic CT coronary calcium scoring.
- Neuro PET — amyloid / FDG dementia workup.
- Theranostic-era imaging — Ga-68 DOTATATE and other isotopes on ToF-configured Biograph 40.
Market position (secondary / refurb)
- Mid-tier Biograph refurb volume — less common than Biograph 16 or 64 but meaningful. Sites that wanted better CT than 16-slice without paying for 64-slice landed here.
- Service ecosystem — shared with Biograph 16 / 64 on the PET side; CT service shared with Sensation 40 standalone CT.
- Successor pathway — Biograph mCT in new orders.
Relationship to siblings
- Biograph 16 — 16-slice entry-tier.
- Biograph 64 — 64-slice flagship of the TruePoint era.
- Biograph Duo — 2-slice predecessor-class.
- Biograph mCT — direct successor generation.