systemSiemensPET CTfamily: biograph-truepoint

Siemens Biograph 40 (TruePoint)

Family: Siemens Biograph TruePoint · Modality: PET/CT

40-slice intermediate tier in the Siemens Biograph TruePoint family. Shares the LSO PET detector architecture with Biograph 16 and Biograph 64, paired with a 40-slice CT derived from the SOMATOM Sensation 40 platform — the CT side brings z-Sharp flying focal spot and the STRATON tube into the PET/CT integrated system. Biograph 40 is less common than Biograph 16 (cost-down entry) and Biograph 64 (premium flagship of its era) but appears meaningfully in the secondary market.

Platform highlights

  • LSO PET detector — 4.0 × 4.0 × 20 mm crystals; same detector architecture as Biograph 16 / 64 TruePoint class.
  • Transaxial FOV 605 mm · Axial FOV 162 mm (216 mm with TrueV option).
  • ToF-capable revisions — ~540 ps coincidence timing on ToF-configured units.
  • 40-slice CT side — shares chassis and tube lineage with SOMATOM Sensation 40. STRATON tube, z-Sharp flying focal spot, CARE Dose4D.
  • Integrated syngo host — shared Siemens operator environment across PET and CT.

CT side (Sensation 40 lineage)

The CT portion of Biograph 40 matches the Sensation 40 standalone CT architecturally:

  • 32-row physical UFC detector with z-Sharp flying focal spot → 40 reconstructed slices.
  • 0.33 s minimum rotation on cardiac-capable configurations.
  • STRATON tube (liquid-metal-bearing rotating anode).
  • 80 kW high-frequency generator.

Specs

  • LSO PET (4.0 × 4.0 × 20 mm)
  • Transaxial FOV 605 mm · Axial FOV 162 mm / 216 mm TrueV
  • 40-slice CT (Sensation 40 lineage)
  • STRATON tube · z-Sharp flying focal spot · CARE Dose4D
  • ToF ~540 ps (ToF-configured revisions)
  • syngo CT + PET host

Clinical positioning

  • Mid-volume oncology PET/CT where 40-slice CT capability is clinically useful — cardiac CTA overlaid with cardiac PET, whole-body staging with diagnostic-quality CT.
  • Cardiac PET/CT — rubidium myocardial perfusion with CT attenuation correction and diagnostic CT coronary calcium scoring.
  • Neuro PET — amyloid / FDG dementia workup.
  • Theranostic-era imaging — Ga-68 DOTATATE and other isotopes on ToF-configured Biograph 40.

Market position (secondary / refurb)

  • Mid-tier Biograph refurb volume — less common than Biograph 16 or 64 but meaningful. Sites that wanted better CT than 16-slice without paying for 64-slice landed here.
  • Service ecosystem — shared with Biograph 16 / 64 on the PET side; CT service shared with Sensation 40 standalone CT.
  • Successor pathwayBiograph mCT in new orders.

Relationship to siblings

Related